To return to the main page of the SSN
667, click here.
How To Throw Out The Trash!
This, my friend, is part of the chores
you had to do to have that many people living in a steel tube. Just like blowing
the sanitary tanks.
What we have is it step by step procedure for shooting the TDU. Trash Disposal
Unit. It's a small torpedo tube affair, with a ballvalve in the end. That's how
they
dump the trash. Weighted it goes straight to the bottom. Now days, I
believe that is kept to a minimum.
TDU FLUSHING PROCEDURE:
MAN JA PHONE AT BCP, TDU, AND PIPING SPACE. OPERATE TDU USING FOLLOWING PHRASEOLOGY AND STEP BY STEP PROCEDURE;
A. BCP; "TDU-BCP, CRACK THE VENT AND CHECK FOR PRESSURE IN TDU. IF NO
PRESSURE IN TDU, OPEN INNER DOOR AND
COMMENCE LOADING."
B. TDU; "BCP-TDU, INNER DOOR IS OPEN; LOADING THE TDU."
C. TDU; "BCP-TDU, TDU IS LOADED AND RIGGED FOR DIVE."
D. BCP; "TDU-BCP,SHIFT THE INTERLOCK TO UNLOCK OUTER DOOR POSITION, OPEN TD
44 STANDBY TO EQUALIZE."
E. TDU; "BCP-TDU, INTERLOCK SHIFTED, TD 44 OPEN. STANDING BY TO
EQUALIZE"
F. BCP; "TDU-BCP,EQUALIZING THE TDU, " BCP OPERATOR OPEN TRIM SEA
VALVE IN TO SEA POSITION CHECK WITH DIVING
OFFICER ON NECESSITY OF FLOODING FROM SEA BEFORE FLUSHING TDU.
G. TDU; "BCP-TDU, TDU IS EQUALIZED, VENT IS SHUT. "(TDU is equalized
when water rises in the vent funnel)
H. BCP; "TDU-BCP, OPEN THE OUTER DOOR AND GIVE MARK WHEN OPEN."
I. TDU; "BCP-TDU, OUTER DOOR INDICATES OPEN." "IF OUTER DOOR IS
NOT OPEN PIPE SPACE REPORT TO BCP."
J. BCP; "TDU-BCP, FLUSHING THE TDU." BCP OPERATOR WILL TAKE SUCTION
FROM TRIM TANK ORDERED BY DIVING OFFICER AND
FLUSH 10,000 LBS THRU TDU.
K. BCP; OPERATOR DECREASE TRIM PUMP RPM TO 2000 RPM. "TDU-BCP, SHUT OUTER
DOOR AND GIVE MARK ON SHUT INDICATION."
SECURE TRIM PUMP ON MARK.
L. TDU; "BCP-TDU, OUTER DOOR INDICATES SHUT. PIPE SPACE VERIFY AND
REPORT."
M. PIPE SPACE; "BCP-PIPE SPACE, OUTER DOOR INDICATES SHUT."
N. BCP; "TDU-BCP, SHUT TD-44; SHIFT INTERLOCKS."
O. TDU; "BCP-TDU, INTERLOCK IS SHIFTED, TD-44 IS SHUT."
P. BCP; "PIPE SPACE-BCP, OPEN TD-320 START AUXILIARY DRAIN PUMP, PUMP DOWN
TDU."
Q. PIPE SPACE; "BCP-TDU PIPE SPACE, TD-320 IS OPEN, DRAIN PUMP RUNNING,
GOOD/NO SUCTION."
R. PIPE SPACE; "BCP-PIPE SPACE, LOST SUCTION ON TDU, TD-320 IS SHUT.
AUXILIARY DRAIN PUMP IS SECURED."
S. BCP; "TDU-BCP, OPEN INNER DOOR, CHECK TDU CLEAR."
T. "BCP-TDU, TDU IS CLEAR AND DRY." IF MORE THAN ONE LOAD IS TO BE
SHOT COMMENCE SEQUENCE AT (B) AGAIN.
U. BCP; "TDU-BCP, SHUT INNER DOOR. RIG TDU FOR DIVE." TDU OPERATOR
SHUT HYDRAULIC SUPPLY TO MUZZLE DOOR OPERATOR,
SHUTS AND TORQUES INNER DOOR.
V. TDU; "BCP-TDU RIGGED FOR DIVE."
W. BCP; "TDU-PIPE SPACE-BCP, SECURE THE PHONES."
All of that to get trash through this little hatch...