War Patrol Report (Page 18)

CONFIDENTIAL  
Subject: U.S.S. BERGALL - Report of SECOND War Patrol
------------------- ---------------------------------------------------------------------------------------------------------
   
(M) RADAR (Continued) -
  SD ELECTRONICS FAILURE
11 Dec. 1944  
Symptom: Distorted sweep
Failure Corrected: Cause of trouble was not located. Trouble was corrected by replacing 2X2, 5049 and CR tube.
Hours Lost: Eight. . . . There were no other electronic failures.
   
(N) SOUND GEAR AND SOUND CONDITIONS -
  None.
   
(O) DENSITY LAYERS -
  None.
   
(P) HEALTH, FOOD, AND HABITABILITY
  No comment.
   
(Q) PERSONNEL -
(a) No. of men on board during patrol ------------------------75
(b) No. of men qualified at start of patrol ----------------------59
(c) No. of men qualified at end of patrol -----------------------59
(d) No. of unqualified men making their first patrol -------------9
(e) No. of men advanced in rating during patrol ----------------0
   
  Our routine training program of two one-hour lectures and practical work a day for unqualified men was disrupted by damage from shell hit; however, the performance of duty under combat conditions of both officers and crew was most excellent.
   
(R) MILES STEAMED - FUEL USED
Base to Area: 1,500 miles / 18,500 gallons
In Area: 3,050 miles / 34,000 gallons
Area to Base: 1,500 miles / 21,000 gallons

Back to Page 17
On to Page 19

Back to the SS 320 home page